AMS 2750F-Qualified operating temperature range
AMS 2750F-Qualified operating temperature rangeWhat's your explanation for the following item?
Let's take an exmaple to clarify if we are on the same page.
One Aging furnace, the norminal setting point temperature is 100℃ - 200℃. The temperature uniformity has been tested which is comply the tolerance is +/-3℃.
Then my question is the qualified temperature range is 100℃ - 200℃ or 97℃ - 203℃?
Thanks very much.
2.2.47 QUALIFIED OPERATING TEMPERATURE RANGE
The nominal set point temperature range of thermal processing equipment where temperature uniformity has been tested
within a qualified work zone and found to be compliant with required tolerances. The qualified operating temperature range
represents the temperature range including ± min/max uniformity tolerances within which parts or raw material can be
processed. (100-200)±3℃ ~~~~~~~~~~~~~~~~ The qualified temperaturerang is 100~200℃ 100-200 C...................... shawnll 发表于 2020-8-5 09:46
The qualified temperaturerang is 100~200℃
Thanks very much.
Couldn't agree with you more 守门员 发表于 2020-7-25 08:54
(100-200)±3℃ ~~~~~~~~~~~~~~~~
Now I think the qualified temperature range is 100℃-200℃ and the tempereture uniformity is +/-3℃.
Right?
页:
[1]